Portfolio

In 2003, Logo established production of optical patch cords, pigtails and preterminated multifiber cables and became recognized as the sole national producer and the leader in the region. We are a local assembly shop licensed by the widely-renowned fiber optic manufacturer HUBER+SUHNER. Besides the standard manufacturing program, our focus is on OEM/ODM production. The entire product portfolio is available in several qualitative assembling classes, thus enabling its customers to achieve optimal technical and financial effects.

Asembling class

  • Singlemode 0,1dB class
  • Insertion Loss

    max. 0.15 dB,
    IEC 61300-3-4
    (against reference measuring)
    ≤ 0.15 dB 97%;
    IEC 61300-3-34
    (each-to-each measuring)
    0.06 dB medium/typical value


  • Return Loss

    > 45db,PC polishing IEC 61300-3-6
    > 50 dB, UPC polishing
    > 85 dB, APC polishing
  • Usage

    Longhaul transimissions saving costs for signal amplification
    Low loss budget transmissions
    Transmissions where uniform channel losses are required
    Low loss budget transmissions
    Splice alternative
  • Singlemode High-End Class
  • Insertion Loss

    max. 0.35 dB,
    IEC 61300-3-4
    (against reference measuring)
    ≤ 0.25 dB 97%;
    IEC 61300-3-34
    (each-to-each measuring)
    0.12 dB medium/typical value


  • Return Loss

    > 45db,PC polishing IEC 61300-3-6
    > 50 dB, UPC polishing
    > 85 dB, APC polishing
  • Usage

    CATV/Video
    PON (Passive Optical Network)
    WDM/DWDM





  • Singlemode LAN-Eco Class
  • Insertion Loss

    max. 0.35 dB,
    IEC 61300-3-4
    (against reference measuring)
    ≤ 0.45 dB 97%,
    IEC 61300-3-34
    (each-to-each measuring)
    0.20 dB medium/typical value


  • Return Loss

    > 45db,PC polishing IEC 61300-3-6
    > 50 dB, UPC polishing
    > 85 dB, APC polishing
  • Usage

    Cost effective connections in PON (Passive Optical Network)
    Universal premises cabling (ISO 11801, EN 50173-1, EIA/TIA 568)
    FTTX, Data center


  • Multimode HQ Class
  • Insertion Loss

    At 1300nm, Launch conditions, IEC 61300-1max.
    max.0.35 dB,
    IEC 61300-3-4
    (against reference measuring)
    ≤ 0.5 dB 97%,
    IEC 61300-3-34
    (each-to-each measuring)
    0.20 dB medium/typical value
  • Return Loss

    > 35 dB
    IEC 61300-3-6


  • Usage

    Universal premises cabling (ISO 11801, EN 50173-1, EIA/TIA 568)
    Data center
    FTTX